Article Index

Technical data of the laser system LMC-J-310-X:

 Measuring data:

  • Measuring range is defined from 0.5 … 3000 m with reflector and 0.5 ... 400 m without reflector
  • Laser divergence is 1-7 mrd, optional 10 mrd
  • Diameter of laser beam in a distance of 300 m is 23 x 78 mm
  • Measuring accuracy at 100 Hz is +/- 20 mm, at 2,000 Hz +/- 60 mm
  • Statistical scattering is +/- 1 cm
  • Resolution of measuring value is 1 mm
  • Measuring times from 0.5 ... 1,000 ms, optional 0.1 ms possible

Connections of the laser device LMC-J-310-X:

  • Connecting can be managed with 1 x 12 pin (Binder Series 723) M18 or 2 x 5 in (Binder Series 766) M12
  • B-encoded
  • Serial interfaces RS 422 or RS 232
  • BR 1.2 … 460.8 kBaud (9.6 kB standard justification); analog output 4 mA ... 20 mA
  • Alarm output 2x „High-Side-Switch“ resistant up to 0.2 A, with window function
  • Trigger 1x in/output up to 30 VDC, shoulder and delay are variable
  • Optional: Profibus (DP-V0 Slave IEC 61158/61784) or SSI 24 bit gray-encoded, 1 validity bit