Page 2 of 3
Technical data of the laser system LMC-J-310-X:
Measuring data:
- Measuring range is defined from 0.5 … 3000 m with reflector and 0.5 ... 400 m without reflector
- Laser divergence is 1-7 mrd, optional 10 mrd
- Diameter of laser beam in a distance of 300 m is 23 x 78 mm
- Measuring accuracy at 100 Hz is +/- 20 mm, at 2,000 Hz +/- 60 mm
- Statistical scattering is +/- 1 cm
- Resolution of measuring value is 1 mm
- Measuring times from 0.5 ... 1,000 ms, optional 0.1 ms possible
Connections of the laser device LMC-J-310-X:
- Connecting can be managed with 1 x 12 pin (Binder Series 723) M18 or 2 x 5 in (Binder Series 766) M12
- B-encoded
- Serial interfaces RS 422 or RS 232
- BR 1.2 … 460.8 kBaud (9.6 kB standard justification); analog output 4 mA ... 20 mA
- Alarm output 2x „High-Side-Switch“ resistant up to 0.2 A, with window function
- Trigger 1x in/output up to 30 VDC, shoulder and delay are variable
- Optional: Profibus (DP-V0 Slave IEC 61158/61784) or SSI 24 bit gray-encoded, 1 validity bit