Laser Distance Sensor LMC-J-0050-X Laser distance sensor  LMC-J-0050-X

precise –robust – reflectorless

The LMC-J-0050-X is a laser distance sensor designed for industrial applications. The device uses a contact less measurement technique based on comparative phase measurement with amplitude modulation. The laser diode has a divergence of 0.6 mrad for measurements at pinpoint accuracy.

The sensor is built in a IP 66 housing which is made for heavy industry area. It includes a special dust protection chamber, which keeps the sensor window much longer clean. The modular construction system of the sensor offers options such as cooling housing, heat shield, exchange windows, 90 ° beam deflection, air purged dust tubes and others.

Parametrization is managed with appropriate interfaces. Standard configuration is defined as a sensor with RS 232 or 422 as well as an analog output 4 … 20 mA. Optional the sensor can be delivered with ProfiBus DP Slave, SSI, Ethernet TCP/IP or W-LAN. 

For safe and easy installation and adjustment the sensor is equipped with a spring cushioned three point bracket as standard solution. Moreover there is a solution with three point bracket for vertical installation.

 

Laser distance measuring device LMC-J-0050-X in service:

  • Detecting distances within millimeter accuracy
  • Exactly defining positions
  • Register movements and recognize objects
  • Level control
  • Measurements on hot surfaces up to 1,200°C, optional up to 1,450 °C
  • Gauge measurement without any optional equipment

 

Features of LMC-J-0050-X:

  • Measurement within millimeter accuracy on diffusley reflecting surfaces
  • Multifunctional use based on customized parametrization
  • Safe use of Laser class 2 (≤1 mW referred to IEC 825-1)
  • Works with red laser light, therefore an easy adjustment of the laser towards the measuring object is possible
  • Compact design:
    • Dimensions (L x W x H): 255 x 90 x 110 mm
    • Weight: app. 4.3 kg
  • Reduced power consumption
  • Supply voltage: 10 - 30 VDC; 10 – 25 VAC; <1,5 W at 24 VDC

 

Options:

  • Vertical installation (Typ B)
  • Exchange window
  • 90° beam deflection
  • Double long front tube for better protection against dust and spray material 
  • Water cooling for ambient temp. up to +100 °C
  • Heat shield
  • Air purge
  • Heating for temperatures down to -40 °C
  • Master slave configuration with signal processing at the master sensor, f.e used for width measurement (only Ethernet and WLan types)